Determination of 19 Polychlorinated Biphenyls in Environmental Sludge Samples by Microwave-assisted Micro-solid Phase Extraction Combined with Gas Chromatography-Mass Spectrometry
|更新时间:
|
Determination of 19 Polychlorinated Biphenyls in Environmental Sludge Samples by Microwave-assisted Micro-solid Phase Extraction Combined with Gas Chromatography-Mass Spectrometry
Vol. 35, Issue 8, Pages: 1036-1040(2016)
作者机构:
东莞理工学院化学与环境工程学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of 19 Polychlorinated Biphenyls in Environmental Sludge Samples by Microwave-assisted Micro-solid Phase Extraction Combined with Gas Chromatography-Mass Spectrometry. [J]. 35(8):1036-1040(2016)
DOI:
Determination of 19 Polychlorinated Biphenyls in Environmental Sludge Samples by Microwave-assisted Micro-solid Phase Extraction Combined with Gas Chromatography-Mass Spectrometry. [J]. 35(8):1036-1040(2016)DOI:
Determination of 19 Polychlorinated Biphenyls in Environmental Sludge Samples by Microwave-assisted Micro-solid Phase Extraction Combined with Gas Chromatography-Mass Spectrometry
A microwave assisted micro-solid phase extraction(MAE-μ-SPE) combined with gas chromatography-mass spectrometric(GC-MS) method was developed for the determination of 19 polychlorinated biphenyls(PCBs) in environmental sludge sample.Target PCBs compounds were extracted from the sludge sample into extraction solvent enhanced by microwave field,followed by adsorption with adsorbent in the micro-solid phase extraction device.The copper(Ⅱ) isonicotinate(Cu(4-C5H4N-COO)2(H2O)4) coordination polymer was prepared and used as the adsorbent.Variables affecting extraction procedures were systematically investigated,and the experimental conditions of MAE-μ-SPE were optimized.The major optimized parameters were as follows:extraction temperature:60 ℃,extraction time:25 min,desorption time:25 min,desorption solvent:150 μL ethyl acetate.Then,a GC-MS method for determination of 19 PCBs was studied.The detection limits(S/N=3) of the method ranged from 0.2 ng/g to 2.5 ng/g,and the relative standard deviations(RSD) were lower than 14%.The mean recoveries were in the range of 81.4%-102.1%.The experimental results demonstrated that the developed MAE-μ-SPE/GC-MS method combining extraction,cleanup,and concentration in one step,was suitable for analysis of trace PCBs in complex samples.
Research Progress of High-throughput and Rapid Detection of Multi-pesticide Residues in Plant-derived Food Samples Based on GC-MS
Recent Advance in Application of Laser Ablation Inductively Coupled Plasma Mass Spectrometry in Environmental Analysis
Analysis of Chloramphenicol,Sulfonamides,Fluoroquinolones,Tetracyclines and Macrolides in Sewage Sludge by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
Application of Microfluidic Chip Electrophoresis in Food Safety and Environmental Analysis
Related Author
No data
Related Institution
Hunan Agricultural Product Processing Institute,Hunan Academy of Agricultural Sciences
Hunan Provincial Key Laboratory of Food Science and Biotechnology,College of Food Science and Technology Hunan Agricultural University