Determination of Nine Haloacetic Acids in Wastewater Effluents Using Reverse Solid phase Extraction Pretreatment and Ultra performance Liquid Chromatography-Tandem Mass Spectrometry
|更新时间:
|
Determination of Nine Haloacetic Acids in Wastewater Effluents Using Reverse Solid phase Extraction Pretreatment and Ultra performance Liquid Chromatography-Tandem Mass Spectrometry
Vol. 35, Issue 11, Pages: 1422-1427(2016)
作者机构:
西安建筑科技大学环境与市政工程学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Nine Haloacetic Acids in Wastewater Effluents Using Reverse Solid phase Extraction Pretreatment and Ultra performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 35(11):1422-1427(2016)
DOI:
Determination of Nine Haloacetic Acids in Wastewater Effluents Using Reverse Solid phase Extraction Pretreatment and Ultra performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 35(11):1422-1427(2016)DOI:
Determination of Nine Haloacetic Acids in Wastewater Effluents Using Reverse Solid phase Extraction Pretreatment and Ultra performance Liquid Chromatography-Tandem Mass Spectrometry
A rapid method for the determination of nine haloacetic acids(HAAs) in wastewater effluent was established using reverse phase solid phase extraction pretreatment coupled with ultra-performance liquid chromatography-tandem mass spectrometry(RSPE UPLC-MS/MS).An ENVI-C18 cartridge was employed to remove organic substances in water sample to minimize its negative effect on HAAs analysis,and the pH value of sample was adjusted to 2.5 to eliminate the effect of inorganic ions on the ionization of HAAs.Under the optimal conditions,all the nine HAAs were separated within 15.0 min on a reversed phase liquid chromatographic column(HSS T3,2.1 mm×100 mm) using methanol-0.000 5% formic acid as mobile phase.The calibration curves were linear(r2=0.999 7-0.999 9) in the range of 0.5-100 μg/L for all the nine HAAs.The limits of detection(LODs) and limits of quantitation(LOQs) were in the range of 0.02-0.26 μg/L and 0.05-0.86 μg/L,respectively.The intra day and inter day relative standard deviations(RSDs) were in the range of 1.4%-10.0% and 1.7% -10.0%,respectively.The method recoveries ranged from 85.2% to 107.8% for effluent samples from three wastewater treatment plants at two spiked concentration levels of 2.5 μg/L and 10 μg/L.This method could meet the detection requirements for nine kinds of HAAs in wastewater effluents.
关键词
卤乙酸超高效液相色谱-串联四极杆质谱二级出水固相萃取
Keywords
haloacetic acidultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)secondary effluentsolid phase extraction(SPE)
Determination of Six Isophthalate Esters in Plastic Toys by Gas Chromatography-Mass Spectrometry with Solid Phase Extraction
Determination of Three Active Components in Tripterygium Wilfordii Hook F. by Activated Carbon Solid Phase Extraction Combined with Micellar Electrokinetic Capillary Chromatography
Analytical Method for Determination of Dinotefuran Residues in Rice and Soil by SPE/HPLC-MS/MS
Determination of 16 Herbicides in Seawater by Solid Phase Extraction/Gas Chromatography-Mass Spectrometry
Determination of 14 Kinds of Ultraviolet Absorbers in Textiles by Solid Phase Extraction Combined with Ultra-high Performance Liquid Chromatography