Determination of Bisphenol A in Milk Sample Using Magnetic Molecularly Imprinted Polymers Solid-phase Extraction Combined with High Performance Liquid Chromatography
|更新时间:
|
Determination of Bisphenol A in Milk Sample Using Magnetic Molecularly Imprinted Polymers Solid-phase Extraction Combined with High Performance Liquid Chromatography
Vol. 36, Issue 2, Pages: 236-241(2017)
作者机构:
韶关学院化学与环境工程学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Bisphenol A in Milk Sample Using Magnetic Molecularly Imprinted Polymers Solid-phase Extraction Combined with High Performance Liquid Chromatography. [J]. 36(2):236-241(2017)
DOI:
Determination of Bisphenol A in Milk Sample Using Magnetic Molecularly Imprinted Polymers Solid-phase Extraction Combined with High Performance Liquid Chromatography. [J]. 36(2):236-241(2017)DOI:
Determination of Bisphenol A in Milk Sample Using Magnetic Molecularly Imprinted Polymers Solid-phase Extraction Combined with High Performance Liquid Chromatography
A new magnetic molecularly imprinted polymers(MIPs) were prepared by using Fe3O4@SiO2 as the support,4-vinyl pyridine(4-VP) as functional monomer,bisphenol A(BPA) as template molecule through surface molecularly imprinted polymerization technology.The structure and morphology of Fe3O4@SiO2-MIPs were characterized by infrared spectroscopy(IR)and transmission electron microscopy(TEM).A new method was established for the separation and enrichment of BPA in milk sample by molecularly imprinted magnetic solid-phase extraction combined with high performance liquid chromatography(HPLC) using Fe3O4@SiO2-MIPs as magnetic adsorbent.The results showed that the Fe3O4@SiO2-MIPs has a high selectivity for BPA under the optimized experimental condition,and the adsorption capacity of Fe3O4@SiO2-MIPs was 13.50 mg/g.The calibration curve of BPA was linear in the range of 0.05-5.0 mmol/L with a correlation coefficient(r2) of 0.993 4.The limit of detection(LOD) was as low as 0.037 μg/L.The proposed method was successfully applied in the determination of BPA in milk sample,with average recoveries of 86.2%-93.1%and relative standard deviations(RSDs) of 2.9%-3.8%at three spiked levels.The developed method is rapid and selective,and is adaptable to the analysis of trace BPA in milk sample.
Adsorption Performance and Mechanism of Ni based Nitrogen doped Magnetic Multi wall Carbon Nanotubes for Bisphenol A
Electrochemical Behavior and Determination of Bisphenol A at ZnO-MWCNTs Composite Modified Electrodes in the Presence of CTAB
Study on Method of Determination of Four Plant Growth Regulater Residues in Watermelons
Simultaneous Determination of Bisphenol A,Octylphenol and Nonylphenol in Skin Care Cosmetics by Liquid Chromatography-Tandem Mass Spectrometry
Simultaneous Determination of Puerarin,3-Methoxy Puerarin,Mirificin and Daidzin in the Bioactive Fraction of Naodesheng Prescription by RP-HPLC/UV Method