Development of microRNA Electrochemical Biosensor Based on Prussian Blue@Graphene-Chitosan Nanocomposite Prepared by in situ Deposition
|更新时间:
|
Development of microRNA Electrochemical Biosensor Based on Prussian Blue@Graphene-Chitosan Nanocomposite Prepared by in situ Deposition
Vol. 36, Issue 5, Pages: 645-649(2017)
作者机构:
成都医学院公共卫生系
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Development of microRNA Electrochemical Biosensor Based on Prussian Blue@Graphene-Chitosan Nanocomposite Prepared by in situ Deposition. [J]. 36(5):645-649(2017)
DOI:
Development of microRNA Electrochemical Biosensor Based on Prussian Blue@Graphene-Chitosan Nanocomposite Prepared by in situ Deposition. [J]. 36(5):645-649(2017)DOI:
Development of microRNA Electrochemical Biosensor Based on Prussian Blue@Graphene-Chitosan Nanocomposite Prepared by in situ Deposition
A microRNA(miR,miRNA) electrochemical biosensor was proposed in the present research.Firstly,graphene(GN) was dispersed in the chitosan(Chi) solution to promote the conductivity of chitosan film.Then,prussian blue(PB) was in situ deposited on GN to obtain the PB@GN-Chi nanocomposite.The obtained nanocomposites were modified on the surface of electrode.Compared with the PB@GN-Chi prepared by ultrasonic method,the prepared composite could effectively prevent PB leaking into detection solution and display a prominent stability when modified on the electrode.The capture probe was subsequently modified by amino group and covalently linked to the modified electrode via glutaraldehyde.After blocked by hexanethiol,the miRNA biosensor was successfully prepared.The prepared PB@GN-Chi nanocomposite was observed with transmission electron microscope,and the electrochemical characteristics of the miRNA biosensor were investigated by cyclic voltammetry and differential pulse voltammetry.Under the optimal conditions,the biosensor displayed a linear relationship between current response and the logarithm of concentration of miR-21 in the range of 2.8-2.8×104 pmol/L.The detection limit was calculated to be 0.87 pmol/L.The prepared biosensor owns good stability and repeatability,and could be employed to detect miR-21 in human serum sample.
An Electrochemical Biosensor for Detection of Protein Kinase Activity Based on Nanoparticle-based Bio-barcode and Hybridication Chain Reaction Amplification Strategy
Detection of 4-Iodophenoxyacetic Acid Using a Graphene-loaded Tin Dioxide Electrochemical Sensor
Detection of microRNA Using an Electrochemical Sensor Based on Target-mediated DNA Self-assembly and Catalytic Current Amplification
Research Progress on Electrochemical Biosensors for SARS-CoV-2 Detection
Related Author
No data
Related Institution
School of Life and Environmental Sciences,Deakin University,Geelong VIC
Key Laboratory of Environmental Functional Materials of Yunnan Province Education Department,School of Chemistry and Environment,Yunnan Minzu University
Laboratory of Chemistry of Xinjiang Specialty Medicinal and Edible Plant Resources, Kashgar University,Kashgar
Institute of Tea Research,Guizhou Academy of Agricultural Sciences
School of Chemical Engineering,Guizhou University for Nationalities