Simultaneous Determination of 5 Substances in the Microbial Enzymatic Reaction System of L-Alanyl-L-glutamine by High Performance Liquid Chromatography and the Influence of Sample Preparation on Chromatographic Peaks
|更新时间:
|
Simultaneous Determination of 5 Substances in the Microbial Enzymatic Reaction System of L-Alanyl-L-glutamine by High Performance Liquid Chromatography and the Influence of Sample Preparation on Chromatographic Peaks
Vol. 35, Issue 10, Pages: 1317-1322(2016)
作者机构:
江南大学生物工程学院工业生物技术教育部重点实验室糖化学与生物技术教育部重点实验室
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Simultaneous Determination of 5 Substances in the Microbial Enzymatic Reaction System of L-Alanyl-L-glutamine by High Performance Liquid Chromatography and the Influence of Sample Preparation on Chromatographic Peaks. [J]. 35(10):1317-1322(2016)
DOI:
Simultaneous Determination of 5 Substances in the Microbial Enzymatic Reaction System of L-Alanyl-L-glutamine by High Performance Liquid Chromatography and the Influence of Sample Preparation on Chromatographic Peaks. [J]. 35(10):1317-1322(2016)DOI:
Simultaneous Determination of 5 Substances in the Microbial Enzymatic Reaction System of L-Alanyl-L-glutamine by High Performance Liquid Chromatography and the Influence of Sample Preparation on Chromatographic Peaks
A method of high performance liquid chromatography(HPLC) with fluorescence detector(FLD) was developed for the simultaneous determination of 5 substances in the microbial enzymatic reaction system of L-alanyl-L-glutamine,including L-alanyl-L-glutamine,L-glutamine,L-alanine methyl ester,L-glutamic acid and L-alanyl-L-alanine.Standard substances and samples were derivated with phthaldialdehyde(OPA) by online automated precolumn derivatization.The analytes were separated on a C18 column using acetonitrile(12%) and 12.5 mmol/L potassium phosphate buffer(88%,pH 7.4) as mobile phase by isocratic elution and analyzed quantitatively by the external standard method at an excitation wavelength of 338 nm and an emission wavelength of 450 nm.The flow rate was set at 1 mL/min and the column temperature was 40 ℃.The calibration curves for five standard substances were all linear in a broad range with correlation coefficients more than 0.999 4.The average recoveries of five substances at three spiked levels ranged from 93.5% to 104.9% with relative standard deviations(RSDs) less than 7%.Injecting six times every two hours one day,the RSD values of retention time for five substances were all less than 0.12%,and the RSD values of peak area of five substances were all less than 1.2%.The method was simple,sensitive,accurate and repeatable with a high resolution.
关键词
高效液相色谱法柱前自动化衍生L-丙氨酰-L-谷氨酰胺反应体系样品处理方法
Keywords
high performance liquid chromatography(HPLC)online automated precolumn derivatizationthe reaction system of L-alanyl-L-glutaminesample preparation
Study on Method of Determination of Four Plant Growth Regulater Residues in Watermelons
Simultaneous Determination of Puerarin,3-Methoxy Puerarin,Mirificin and Daidzin in the Bioactive Fraction of Naodesheng Prescription by RP-HPLC/UV Method
Determination of Vitamin K1 in Cosmetics by High Performance Liquid Chromatography
Analysis of Four N-Substituted Derivatives of p-Phenylenediamine in Hair Dyes by High Performance Liquid Chromatography
Simultaneous Determination of Para Red and Four Sudan Dyes Residues in Eggs by Dispersive Solid-phase Extraction Combined with High Performance Liquid Chromatography