Simultaneous Determination of Twelve Anticoagulant Rodenticides in Clinical Dried Blood Spots by Liquid Chromatography-Tandem Mass Spectrometry
|更新时间:
|
Simultaneous Determination of Twelve Anticoagulant Rodenticides in Clinical Dried Blood Spots by Liquid Chromatography-Tandem Mass Spectrometry
Vol. 36, Issue 11, Pages: 1296-1303(2017)
作者机构:
1. 军事医学科学院毒物药物研究所
2. 抗毒药物与毒理学国家重点实验室
3. 军事医学科学院附属医院中毒救治科
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Simultaneous Determination of Twelve Anticoagulant Rodenticides in Clinical Dried Blood Spots by Liquid Chromatography-Tandem Mass Spectrometry. [J]. 36(11):1296-1303(2017)
DOI:
Simultaneous Determination of Twelve Anticoagulant Rodenticides in Clinical Dried Blood Spots by Liquid Chromatography-Tandem Mass Spectrometry. [J]. 36(11):1296-1303(2017)DOI:
Simultaneous Determination of Twelve Anticoagulant Rodenticides in Clinical Dried Blood Spots by Liquid Chromatography-Tandem Mass Spectrometry
To address the fast detection need towards poisoned patients in clinic,a sensitive,accurate liquid chromatographic-tandem mass spectrometric method was developed here for the qualitative and quantitative determinations of twelve anticoagulant rodenticides in dried blood spots.For the thoroughly punched dried blood spots,conditions influencing the extraction efficiency,including the kind of filter paper card,the water-soaking step and the kind of extraction solvent were investigated.A C18 column was employed as separation phase while ammonium acetate in water(5mmol/L)-ammonium acetate in methanol(5mmol/L) was used as mobile phase by gradient elution.Then the sample was detected using negative electrospray ionization under multiple reaction monitoring mode.The results showed that,with the 903 type filter card as supporting matrix and a water-soaking step,followed by an extraction with methanol solvent containing internal standard for 5min,the extraction efficiencies of the twelve rodenticides ranged from 66% to 115% with their intra-day relative standard deviations less than 15%.Good method validation results were obtained for all the anticoagulant rodenticides.The linearity for pindone was from 20 to 500 ng/mL with a correlation coefficient(r2) of 0.9987,and that for the other eleven analytes were from 5 to 500ng/mL with their r2 of 0.9988-0.9996. The recoveries for all the analytes ranged from 61% to 105%,with the matrix effects of 71%-193% and the intra-day relative standard deviations less than 15%.The established method was accurate,sensitive,rapid and convenient,and was successfully applied in the rapid detection of rodenticides in three clinic blood samples. It provides a new approach for clinical diagnosis and forensic toxicant analysis on anticoagulant rodenticide intoxication accidents.
关键词
干血斑抗凝血杀鼠药液相色谱-串联质谱法临床中毒快检
Keywords
dried blood spotanticoagulant rodenticideliquid chromatography-tandem mass spectrometryfast detection on poisoned clinical samples
Rapid Screening for 34 Benzodiazepines in Dried Blood Spots Using Direct Analysis in Real Time-Tandem Mass Spectrometry
Determination of Free Thyroid Hormones in Serum by Gel Filtration Chromatography Combined with Liquid Chromatography-Tandem Mass Spectrometry
Rapid Determination of Enramycin Residues in Swine Liver by Liquid Chromatography-Tandem Mass Spectrometry
Determination of Glyphosate and Aminomethylphosphonic Acid in Plant-derived Foodstuff by Aqueous Normal Phase(ANP) Chromatography-Tandem Mass Spectrometric Method
Related Author
No data
Related Institution
School of Criminal Investigation,People’s Public Security University of China
Forensic Science Service of Beijing Public Security Bureau,Key Laboratory of Forensic Toxicol,Ministry of Public Security
Institue of Materia Medica,Peking Union Medical College,Chinese Academy of Medical Science
Chengdu Institute of Biology,Chinese Academy of Sciences
Chengdu Institute of Organic Chemistry,Chinese Academy of Sciences