Rapid Determination of Five Artificial Sweeteners,Six Iodinated X-ray Contrast Agents and Caffeine in Different Water Samples by Solid Phase Extraction with Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
|更新时间:
|
Rapid Determination of Five Artificial Sweeteners,Six Iodinated X-ray Contrast Agents and Caffeine in Different Water Samples by Solid Phase Extraction with Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
Vol. 36, Issue 7, Pages: 876-881(2017)
作者机构:
1. 中国科学院广州地球化学研究所有机地球化学国家重点实验室
2. 中国科学院大学
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Rapid Determination of Five Artificial Sweeteners,Six Iodinated X-ray Contrast Agents and Caffeine in Different Water Samples by Solid Phase Extraction with Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 36(7):876-881(2017)
DOI:
Rapid Determination of Five Artificial Sweeteners,Six Iodinated X-ray Contrast Agents and Caffeine in Different Water Samples by Solid Phase Extraction with Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 36(7):876-881(2017)DOI:
Rapid Determination of Five Artificial Sweeteners,Six Iodinated X-ray Contrast Agents and Caffeine in Different Water Samples by Solid Phase Extraction with Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
An ultra performance liquid chromatography-tandem mass spectrometric(UPLC-MS/MS) method was developed for the rapid determination of 5 artificial sweeteners,6 iodinated X-ray contrast agents and caffeinein in various water samples(surface water,inflow and effluent for wastewater treatment plant). The filtered water samples were extracted,and purified through HR-X solid phase extraction cartridges and separated on a Zorbax SB-C18 column. The determination of analytes was performed under multiple reaction monitoring(MRM) mode using acetonitrile-water(10 mmol/L ammonium acetate,0.01% formic acid) and acetonitrile-water(5 mmol/L ammonium acetate,1 mmol/L Tris) as mobile phases in positive ionization mode and negative ionization mode,respectively. The calibration curves of the target compounds were linear in the range of 5-5 000 μg/L with correlation coefficients more than 0.998. The recoveries of the target compounds in surface water,inflow and effluent were all between 70% and 120%,with relative standard deviations(RSD) of 0.8%-19.0%. The method detection limits(MDL) for three types of water samples were in the ranges of 0.43-13.8 ng/L,1.80 -34.8 ng/L and 2.30-134 ng/L,respectively. The method was successfully applied in the determination of artificial sweeteners,iodinated X-ray contrast agents and caffeine in different actual water samples collected from a wastewater treatment plant and its receiving river from Guangzhou city. Except for aspartame,iothalamic acid,iopromide and iomeprol,the other compounds were all detected with high concentrations. The established method is accurate,sensitive and simple,and is suitable for the determination of artificial sweeteners,iodinated X-ray contrast agents and caffeine in various environmental water samples.
关键词
人造甜味剂造影剂咖啡因超高效液相色谱-串联质谱水样
Keywords
artificial sweetenersiodinated X ray contrast agentscaffeineultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)water samples
Simultaneous Separation and Determination of Three Active Ingredients in Paracetamol Caffeine Aspirin Powder by Micellar Electrokinetic Capillary Chromatography
Determination of Acetaminophen,Caffeine and Chlorphenamine Maleate in Compound Paracetamol and Amantadine Hydrochloride Capsules by Sweeping-MEKC Method
Separation and Determination of Effective Compounds in Alkaloidal Samples by Capillary Zone Electrophoresis
Rapid Determination of Caffeine in Milk Tea by Pseudo Reversed Phase Liquid Chromatography
Determination of Caffeine Using an Electrochemical Sensor Based on the Electropolymerized Molecularly Imprinted Film on a Multi-walled Carbon Nanotube Modified Glassy Carbon Electrode