Rapid Screening of 28 Pesticides Endocrine Disruptors in Aquatic Products by Ultrahigh Performance Liquid Chromatography-Quadrupole/Electrostatic Field Obitrap High-resolution Mass Spectrometry
|更新时间:
|
Rapid Screening of 28 Pesticides Endocrine Disruptors in Aquatic Products by Ultrahigh Performance Liquid Chromatography-Quadrupole/Electrostatic Field Obitrap High-resolution Mass Spectrometry
Vol. 36, Issue 12, Pages: 1445-1451(2017)
作者机构:
1. 威海出入境检验检疫局
2. 山东出入境检验检疫局
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Rapid Screening of 28 Pesticides Endocrine Disruptors in Aquatic Products by Ultrahigh Performance Liquid Chromatography-Quadrupole/Electrostatic Field Obitrap High-resolution Mass Spectrometry. [J]. 36(12):1445-1451(2017)
DOI:
Rapid Screening of 28 Pesticides Endocrine Disruptors in Aquatic Products by Ultrahigh Performance Liquid Chromatography-Quadrupole/Electrostatic Field Obitrap High-resolution Mass Spectrometry. [J]. 36(12):1445-1451(2017)DOI:
Rapid Screening of 28 Pesticides Endocrine Disruptors in Aquatic Products by Ultrahigh Performance Liquid Chromatography-Quadrupole/Electrostatic Field Obitrap High-resolution Mass Spectrometry
A rapid method was developed for the screening and quantification of 28 pesticides endocrine disruptors in aquatic products by ultrahigh performance liquid chromatography-quadrupole/electrostatic field obitrap high-resolution mass spectrometry.The samples were extracted with ethyl acetate,and purified with a Captiva ND Lipids column.The separation was carried out on an ACQUITY UPLC@BEN C18 column(2.1 mm×50 mm,1.7 μm) with methanol-water as mobile phases by gradient elution.The 28 pesticides endocrine disruptors were simultaneously analyzed in switching positive and negative modes.The retention time,accurate mass of parent ion and relative isotope abundance were used for fast screening in full scan mode,while accurate mass of fragment ions were used for comfirmation in two-stage threshold-triggered full mass scan mode.Under the optimal conditions,good linearities(r2>0.99) were obtained in their respective linear ranges.The limits of detections(LODs) for most compounds were not more than 10 μg/kg except for acetochlor,procymidone and fenitrothion.The recoveries were in the range of 65.7%-98.9% and the relative standard deviations(RSDs) were 6.2%-11.3%.The method was simple,sensitive and accurate,and was suitable for the rapid screening and confirmation of multiple pesticides endocrine disruptors in aquatic products.
关键词
超高效液相色谱静电场轨道阱高分辨质谱农药环境激素快速筛查
Keywords
ultra-performance liquid chromatographyobitrap high-resolution mass spectrometrypesticidesendocrine disruptorsrapid screening
Rapid Screening of 32 Dyes in Oxidative Hair Dyes by Ultra-performance Liquid Chromatography-Quadrupole/Electrostatic Field Obitrap High-resolution Mass Spectrometry
Rapid Screening for 34 Benzodiazepines in Dried Blood Spots Using Direct Analysis in Real Time-Tandem Mass Spectrometry
Rapid Screening of Chemical Risk Substances in Honey by Sugar Extraction/Ultra High Performance Liquid Chromatography-Quadrupole/Electrostatic Field Orbitrap High Resolution Mass Spectrometry
Rapid Screening of 112 Kinds of Illegally Added Chemical Compounds in Anti-fatigue Health Food by Ultra-high Performance Liquid Chromatography Quadrupole Electrostatic Field Orbital Trap Mass Spectrometry
Determination of 71 Kinds of Pesticide Residues in Milk by Gas Chromatography-Exactive Orbitrap Mass Spectrometry with Modified QuEChERS Method
Related Author
No data
Related Institution
威海海关
日照海关
Institue of Materia Medica,Peking Union Medical College,Chinese Academy of Medical Science
Forensic Science Service of Beijing Public Security Bureau,Key Laboratory of Forensic Toxicol,Ministry of Public Security
School of Criminal Investigation,People’s Public Security University of China