Screening and Detection of Antibiotics in Fish Pond Water by Ultra Performance Liquid Chromatography-Mass Spectrometry with Solid Phase Extraction
|更新时间:
|
Screening and Detection of Antibiotics in Fish Pond Water by Ultra Performance Liquid Chromatography-Mass Spectrometry with Solid Phase Extraction
Vol. 37, Issue 3, Pages: 275-281(2018)
作者机构:
1. 北京化工大学理学院
2. 北京市环境保护检测中心
3. 北京市疾病预防控制中心北京市食物中毒溯源诊断重点实验
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Screening and Detection of Antibiotics in Fish Pond Water by Ultra Performance Liquid Chromatography-Mass Spectrometry with Solid Phase Extraction. [J]. 37(3):275-281(2018)
DOI:
Screening and Detection of Antibiotics in Fish Pond Water by Ultra Performance Liquid Chromatography-Mass Spectrometry with Solid Phase Extraction. [J]. 37(3):275-281(2018)DOI:
Screening and Detection of Antibiotics in Fish Pond Water by Ultra Performance Liquid Chromatography-Mass Spectrometry with Solid Phase Extraction
A method was established for the rapid detection of 15 kinds of antibiotics(quinolones,chloramphenicol,tetracycline and sulfonamides) in river water near fish farms by ultra performance liquid chromatography-tandem triple quadrupole mass spectrometry(UPLC-MS/MS) with solid-phase extraction.After filtration,a 500 mL of water sample was adjusted to pH 4.0 with hydrochloric acid,then added 0.5 g ethylenediaminetetraacetic acid disodium(Na2EDTA) to removal the interference of variousmetal ions,and finally enriched with an HLB solid-phase extraction column.The sample was detected by ultra performance liquid chromatography couple with quadrupole time-of-flight mass spectrometry(UPLC-Q-TOF MS),and screened for the antibiotics with antibiotic library.The corfirmation and quantitation of antibiotics in the sample were performed by UPLC-MS/MS in multi-period multi-reaction monitoring ion mode(MRM) with external standard method.The spiked recoveries for 15 antibiotics in blank matrix were in the range of 61.0%-98.4% with the relative standard deviations(n=3) of 4.6%-14.0%.The calibration curves of 15 antibiotics showed good linearity with the correlation coefficients not less than 0.990.The method detection limits(MDLs) ranged from 0.01 ng/L to 0.3 ng/L.With high sensitivity and good repeatability,this method could be applied in the detection of antibiotics in fish pond water in Beijing.
Determination of Sulfonamides and Tetracyclines Antibiotics in Surface Sediments by Reversed Phase High Performance Liquid Chromatography
Determination of 43 Persistent Organochlorine Pollutants in Human Serum by Gas Chromatography-Tandem Mass Spectrometry
Simultaneous Detection of Pesticides and Antibiotics Residues in Soil by QuEChERS/Ultra Performance Liquid Chromatography- Tandem Mass Spectrometry
Determination of Ethoxyquinoline and Ethoxyquinoline Dimer in Aquatic Products by High Performance Liquid Chromatography-Tandem Mass Spectrometry
Determination of Fipronil and Its Metabolites in Rice Fishing Water Samples by SPE/UPLC-MS/MS
Related Author
No data
Related Institution
上海市杨浦区环境监察支队
水域环境生态上海高校工程研究中心
上海海洋大学水产与生命学院
School of Public Health, Anhui Medical University
National Institute of Environmental Health,Chinese Center for Disease Control and Prevention,China CDC Key Laboratory of Environment and Population Health