Determination of Amino Acids in Feed by High Performance Liquid Chromatography with Microwave Hydrolysis Derivatization
|更新时间:
|
Determination of Amino Acids in Feed by High Performance Liquid Chromatography with Microwave Hydrolysis Derivatization
Vol. 36, Issue 10, Pages: 1255-1259(2017)
作者机构:
河北农业大学食品科技学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Amino Acids in Feed by High Performance Liquid Chromatography with Microwave Hydrolysis Derivatization. [J]. 36(10):1255-1259(2017)
DOI:
Determination of Amino Acids in Feed by High Performance Liquid Chromatography with Microwave Hydrolysis Derivatization. [J]. 36(10):1255-1259(2017)DOI:
Determination of Amino Acids in Feed by High Performance Liquid Chromatography with Microwave Hydrolysis Derivatization
A high performance liquid chromatographic(HPLC) method with microwave hydrolysis derivation was developed for the simultaneous determination of 17 amino acids in feed.The method was based on pre-column derivatization with 2,4-dinitro-chlorobenzene.The compounds were separated on a C18 column.And the conditions of microwave hydrolysis were optimized.The detection was performed using a diode array detector at 360 nm.The calibration curves of 17 amino acids all exhibited good linearities in the range of 2.5-50 mg/L.The correlation coefficients(r2) for the determination varied between 0.990 7 and 0.999 9 with the relative standard deviations(RSDs) of 0.88% to 4.2%,and the recoveries of 17 amino acids were in the range of 90.6%-107.2% with the limits of detection of 0.15-2.37 mg/L.The results showed that the results of microwave hydrolysis in 16 min at 150 ℃ are basically the same as those of traditional heating hydrolysis(110 ℃,24 h).With the advantages of short analysis time,high sensitivity,the method could be used for the determination of amino acids in feed.
Study on the Compound Specific Carbon Stable Isotope Determination of Amino Acids in Organisms
Analysis of Macrolide Antibiotics in Feeds by High Performance Liquid Chromatography-Tandem Mass Spectrometry Based on Solid Phase Extraction
Evaluation of Quality Parameters in Fuling Mustard Tuber by Fourier Transform Near Infrared Spectroscopy
Simultaneous Determination of Chloramphenicol,Thiamphenicol and Florfenicol Residues in Feed by High Performance Liquid Chromatography-Tandem Mass Spectrometry
Quantitative Analysis of Amino Acids in Eptifibatide Injection by RP-HPLC
Related Author
No data
Related Institution
Zhoushan Field Scientific Observation and Research Station for Marine Geo-hazards,China Geological Survey
Information and Testing Support Center,Third Institute of Oceanography,Ministry of Natural Resources