Determination of Disodium Ethylenediaminotetraacetic Acid in Flour and Its Products by High Performance Liquid Chromatography
|更新时间:
|
Determination of Disodium Ethylenediaminotetraacetic Acid in Flour and Its Products by High Performance Liquid Chromatography
Vol. 36, Issue 10, Pages: 1230-1234(2017)
作者机构:
厦门出入境检验检疫局检验检疫技术中心
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Disodium Ethylenediaminotetraacetic Acid in Flour and Its Products by High Performance Liquid Chromatography. [J]. 36(10):1230-1234(2017)
DOI:
Determination of Disodium Ethylenediaminotetraacetic Acid in Flour and Its Products by High Performance Liquid Chromatography. [J]. 36(10):1230-1234(2017)DOI:
Determination of Disodium Ethylenediaminotetraacetic Acid in Flour and Its Products by High Performance Liquid Chromatography
In the absence of ion-pair reagents or high-salt buffer condition,a novel method for the quantitative analysis of disodium ethylenediaminotetraacetic acid in flour and its products by high performance liquid chromatography was developed,employing hydrophilic C18 reversed-phase liquid chromatography column and methanol-water system as mobile phase.Samples were extracted with aqueous solution,and reacted with ferric chloride by ultrasound irradiation to product stable derivative which was cleaned up with trichloromethane.To determine ethylenediaminotetraacetic acid disodium in flour and flour products,the analytes were determined by high performance liquid chromatography with a wavelength of 260 nm and a hydrophilic C18 reversed phase liquid chromatography column using mobile phases of pH 4.0 methanol and aqueous solution(10∶90,by volume).Under the optimal conditions,the calibration curves of the analytes were linear in the concentration range of 1.0-50.0 mg/L with the correlation coefficients of 0.999 6.The limits of quantification(LOQs) were 10.0 mg/kg,and the limits of detection(LODs) were 3.0 mg/kg.At spiked levels of 10.0-200 mg/kg,the average recoveries of spiked samples ranged from 95.0%to 103%,with relative standard deviations between 4.0%and 6.3%.The method could meet the requirement for the rapid screening and quantitative analysis of disodium ethylenediaminotetraacetic acid in flour and its products.
Detection of Seven Quinolones in Honey by High Performance Liquid Chromatography with Effervescent Assisted Liquid Phase Microextraction
Simultaneous Determination of 19 Organic Antibacterial Agents in Tissue Paper and Paper Products by High Performance Liquid Chromatography
Simultaneous Determination of Three Diabetic Drugs in Urine by High Performance Liquid Chromatography
Simultaneous Determination of Vanillin and o Vanillin by High Performance Liquid Chromatography
Simultaneous Determination of Ten Synthetic Colours in Ice-cream by High Performance Liquid Chromatography
Related Author
No data
Related Institution
Institute of Agricultural Quality Standards and Testing Technology,Tianjin Academy of Agricultural Sciences
Tianjin Key Laboratory of Agricultural Animal Breeding and Healthy Husbandry,College of Animal Science and Veterinary Medicine,Tianjin Agricultural University
Guangdong Testing Institute of Product Quality Supervision, Shunde