Electrocatalytic Behaviors of Furosemide at APTS and Graphene Modified Carbon Paste Electrode and Its Electrochemical Determination
|更新时间:
|
Electrocatalytic Behaviors of Furosemide at APTS and Graphene Modified Carbon Paste Electrode and Its Electrochemical Determination
Vol. 36, Issue 11, Pages: 1333-1338(2017)
作者机构:
1. 银川能源学院石油化工系
2. 宁夏出入境检验检疫局
3. 宁夏大学化学化工学院
4. 宁夏宝塔化工中心实验室
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Electrocatalytic Behaviors of Furosemide at APTS and Graphene Modified Carbon Paste Electrode and Its Electrochemical Determination. [J]. 36(11):1333-1338(2017)
DOI:
Electrocatalytic Behaviors of Furosemide at APTS and Graphene Modified Carbon Paste Electrode and Its Electrochemical Determination. [J]. 36(11):1333-1338(2017)DOI:
Electrocatalytic Behaviors of Furosemide at APTS and Graphene Modified Carbon Paste Electrode and Its Electrochemical Determination
In this paper,the electrochemical behavior of furosemide(FUR) at 3-anminopro-pyltriethoxsilane(APTS) and graphene(RGO) modified carbon paste electrode(APTS-RGO/CPE) was studied.The experimental results indicated that compared with CPE,APTS-RGO/CPE showed a good promotion towards FUR electrochemical oxidation,and the oxidation peak current increased significantly.Cyclic voltammetry(CV) and chronoamperometry(CA) were used to determine the reaction kinetics parameters of FUR on the APTS-RGO/CPE electrode.The relationship between FUR oxidation peak current and its concentration was evaluated by differential pulse voltammetry(DPV).The oxidation peak current of FUR and its concentration has a good linear relationship in the concentration range of 1.3-330 mg/L with the limit of detection(S/N=3) of 1.1×10-2 mg/L.The proposed method was successfully applied in the determination of commercial tablet samples,with their relative standard deviations of 0.4%-4.4%and recoveries of 98.5%-99.7%.The results were in accord with the requirement of quantitative detection.
Electrochemical Behaviors of Meloxicam at AB and [BnMIM]PF6 Modified Carbon Paste Electrode and Its Electrochemical Determination
Detection of 4-Iodophenoxyacetic Acid Using a Graphene-loaded Tin Dioxide Electrochemical Sensor
Progress in DNA Sequencing Based on Graphene Nanomaterials
In-situ Preparation of a Solid Phase Microextraction Probe Based on Graphene Self assembly and Its Application in Determination of Benzene Series in Water
Research on Sensitive Determination of Daphnetin Using an Electrochemical Sensor Based on PSS Functionalized Spongy Graphene
Related Author
No data
Related Institution
银川大学石油化工学院
Laboratory of Chemistry of Xinjiang Specialty Medicinal and Edible Plant Resources, Kashgar University,Kashgar
School of Chemical Engineering,Guizhou University for Nationalities
Institute of Tea Research,Guizhou Academy of Agricultural Sciences