In this paper,a self assembled impedance immune sensor was constructed to detect trace Tau protein in order to achieve the purpose of early diagnosis on Alzheimer disease.The sensor was constructed and characterized by the following steps:the bifunctional molecule 3,3′ dithiobis(sulfosuccinimidylpropionate) (DTSSP) was modified on the gold electrode surface through the Au-S bond,which was then conjugated with antibodies 39E10 through the CO-NH.Tau protein was specifically captured by physisorption using immunoassay,characterized by AC impedance and verified by cyclic voltammetry.By optimizing the DTSSP modification time and antibody concentration,the sensor had a detection signal toward Tau protein of 002-100 μg/mL,in which there existed a good linearity(r2=0988 8) in the concentration range of 02-20 μg/mL with a detection limit of 043 nmol/L.This immunosensors specific capture ability for Tau could be used as a supplementary means for clinical detection on AD.
关键词
电化学阻抗免疫阿尔兹海默症tau蛋白
Keywords
electrochemistryimpedanceimmunityAlzheimer disease(AD)tau protein