Detection of Radon Using a Label-free Fluorescence Sensor Based on Combination of Pb2+-induced Allosteric T30695 with N-Methyl Mesoporphyrin Ⅸ
|更新时间:
|
Detection of Radon Using a Label-free Fluorescence Sensor Based on Combination of Pb2+-induced Allosteric T30695 with N-Methyl Mesoporphyrin Ⅸ
Vol. 38, Issue 6, Pages: 643-648(2019)
作者机构:
南华大学公共卫生学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Detection of Radon Using a Label-free Fluorescence Sensor Based on Combination of Pb2+-induced Allosteric T30695 with N-Methyl Mesoporphyrin Ⅸ. [J]. 38(6):643-648(2019)
DOI:
Detection of Radon Using a Label-free Fluorescence Sensor Based on Combination of Pb2+-induced Allosteric T30695 with N-Methyl Mesoporphyrin Ⅸ. [J]. 38(6):643-648(2019)DOI:
Detection of Radon Using a Label-free Fluorescence Sensor Based on Combination of Pb2+-induced Allosteric T30695 with N-Methyl Mesoporphyrin Ⅸ
A fluorescent sensor was fabricated for the detection of radon based on the daughter lead inducing G-rich aptamer T30695 to form G-quadruplex.According to the characteristics of radon radioactive decay,it only takes about 3.82 days for radon to decay and form a stable daughter lead,and 210Pb derived from radon decay is very stable.The half-life period of the stable daughter(210Pb)resulted from radon is 21 years,and the lead daughter product could be used as the target for detection.When there was no lead in the system,T30695 combined with its complementary chain to form a double-stranded DNA structure,and the fluorescent signal of N-methyl mesoporphyrin IX(NMM)was weak.When the system contained daughter lead,aptamer T30695 was induced to form a G-quadruplex structure,and NMM combined with G-quadruplex structure to produce strong fluorescence.Within a certain range, the fluorescence intensity is positively correlated with the concentration of Pb2+ and radon.There existed a linear relationship btween the fluorescence value(ΔIF)of reaction system and Pb2+ concentration in the range of 5.13×10-9-1.25×10-7 mol/L,with a linear regression equation of ΔIF=77.30+5.05c,a detection limit of 1.54×10-9 mol/L and a correlation coefficient(r)of 0.995 0.The detection limit for radon was 1.07×104 Bq?h/m3.
G-quadruple/Hemin DNAzyme-based Visual Detection of the Folding Structure Formed by d(GGA) Trinucleotide Repeats
Determination of Ochratoxin A Using a Cathodic Photoelectrochemical Sensor Based on AgBr-Ag-CNTs Composite and Aptamer
Detection of Vibrio Parahaemolyticus by an Aptameric Fluorescence Method Based on Metal Organic Framework Material and Enzyme-assisted Signal Amplification
Detection of Mercury by a Label-free Aptamer-based Fluorescent Assay
Related Author
No data
Related Institution
Hangzhou Institute of Medicine(HIM),Chinese Academy of Sciences,Hangzhou
Institute of Resources and Environment,Henan Polytechnic University,Jiaozuo
Hangzhou Institute of Medicine(HIM),Chinese Academy of Sciences
Institute of Resources and Environment,Henan Polytechnic University
College of Biological and Agricultural Science and Technology,Zunyi Normal University