Simultaneous Determination of Residual Glycol Ethers and Their Acetates in Dyeing and Finishing Additives by Gas Chromatography-Tandem Mass Spectrometry
|更新时间:
|
Simultaneous Determination of Residual Glycol Ethers and Their Acetates in Dyeing and Finishing Additives by Gas Chromatography-Tandem Mass Spectrometry
Vol. 38, Issue 10, Pages: 1213-1219(2019)
作者机构:
1. 深圳海关工业品检测技术中心
2. 深圳职业技术学院应用化学与生物技术学院
3. 深圳市检验检疫科学研究院
4. 江苏海关工业产品检测中心
5. 香港理工大学应用生物及化学科技学系
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Simultaneous Determination of Residual Glycol Ethers and Their Acetates in Dyeing and Finishing Additives by Gas Chromatography-Tandem Mass Spectrometry. [J]. 38(10):1213-1219(2019)
DOI:
Simultaneous Determination of Residual Glycol Ethers and Their Acetates in Dyeing and Finishing Additives by Gas Chromatography-Tandem Mass Spectrometry. [J]. 38(10):1213-1219(2019)DOI:
Simultaneous Determination of Residual Glycol Ethers and Their Acetates in Dyeing and Finishing Additives by Gas Chromatography-Tandem Mass Spectrometry
An effective method was established for the simultaneous determination of fifteen glycol ethers and four glycol ether acetates residues in dyeing and finishing additives by gas chromatography-tandem mass spectrometry(GC-MS/MS).Residual glycol ethers and their acetates in dyeing and finishing additives were ultrasonically extracted with ethyl acetate as extraction solvent.The extract was then purified using a Waters Sep-Pak Vac Silica(1 g/6 mL) solid phase extraction(SPE) column.The chromatographic separation of 19 target compounds was performed on a DB-Wax(60 m×0.25 mm×0.25 μm) column.GC-MS/MS analysis was carried out in multiple reaction monitoring(MRM) mode,and the concentrations of glycol ethers and their acetates were calibrated by the external standard method.The peak areas(A) for the analytes were linearly related to their mass concentrations(ρ) in each linear range,and the correlation coefficients were no less than 0.999 2.The limits of detection(LODs) and quantitation(LOQs) of the method were calculated by the signal to noise(S/N) ratios of three and ten,respectively.LODs for MOPA and DEGME were both 30 μg/kg,LOD for DEGDEE was 20 μg/kg,LODs for EGEE and EGME were 10 μg/kg,and LODs for the other fourteen target compounds ranged from 1 μg/kg to 5 μg/kg,while LOQs for EGEE,EGME and DEGDEE were 20,30 and 50 μg/kg,respectively,while that for MOPA and DEGME were both 100 μg/kg,and LOQs for the other fourteen varied from 1 μg/kg to 15 μg/kg.The average recoveries at three spiked levels ranged from 82.4% to 94.6% with the relative standard deviations(RSDs) of 2.7% to 9.2%.The proposed method was simple and sensitive,and could meet completely the demands for routine analysis of residual glycol ethers and their acetates in dyeing and finishing additives.
关键词
气相色谱-串联质谱法(GC-MS/MS)染整助剂乙二醇醚乙二醇醚醋酸酯超声萃取
Keywords
gas chromatography-tandem mass spectrometry(GC-MS/MS)dyeing and finishing additivesglycol ethersglycol ether acetatesultrasonic extraction
Determination of Residues of 21 Harmful Organic Solvents in Leather and Leather Products by Gas Chromatography-Mass Spectrometry Combined with Ultrasonic Extraction
Simultaneous Determination of Thirteen Organophosphate Retardants in Lithium ion Battery Electrolyte by Gas Chromatography-Tandem Mass Spectrometry
Simultaneous Determination of Six Kinds of Banned Organophosphorous Flame Retardants in Textiles by Gas Chromatography Tandem Mass Spectrometry Combined with Ultrasonic Extraction
Determination of Three Furfurals in Condimen by Gas Chromatography-Tandem Mass Spectrometry
Simultaneous Determination of 20 Kinds of Phthalate Plasticizers in Leather Products by Gas Chromatography-Tandem Mass Spectroscopy Coupled with Ultrasonic Extraction