a “turn off” fluorescent sensor based on aptamer functionalized grapheme oxide(GO) decorated gold nanoparticles(AuNPs) composites was developed for the detection of Hg2+.Firstly
the GO@AuNPs with certain fluorescence properties were fabricated by wet chemical method
then the sulfhydryl modified single chain T-rich nucleic acid DNA(aptamer) was immobilized on the surface of gold nanoparticles to form aptamer functionalized graphene oxide decorated gold nanoparticles complexes(aptamer-GO@AuNPs).In the presence of Hg2+
due to the coordination of seven T-Hg2+-T structures
T-rich aptamer was folded to form a rigid and double stranded hairpin structure
making coordinated Hg2+ close to the graphene surface(less than 1 nm).In that case
electrons could transfer from graphene to mercury ion along the double stranded DNA channel
which caused the graphene fluorescence quenched.Based on this
a “turn-off” fluorescence sensor was constructed.Under the optimal experimental conditions
the linear detection range for Hg2+ was 0.5-80 nmol/L
and the detection limit was 0.3 nmol/L.The method was applied in the detection of Hg2+ in environmental water samples.The recoveries ranged from 96.0% to 105% with the relative standard deviations of 1.4%-3.2%.With the advantages of simple operation
strong anti-interference
high sensitivity and selectivity
label-free and rapid detection
the method could be used for the high sensitive detection of Hg2+ in environmental water samples.