Estudo de detecção rápida de biomarcadores da nefropatia diabética baseado no método imuno-turbidimétrico com smartphone

  • role: First author第一作者
  • Affiliation:

    Institute of Biomedical Precision Testing and Instrumentation,College of Artificial Intelligence,Taiyuan University of Technology,Jinzhong 030600,China

ZHANG Ya-qiong,  
  • Affiliation:

    Institute of Biomedical Precision Testing and Instrumentation,College of Artificial Intelligence,Taiyuan University of Technology,Jinzhong 030600,China

YANG Yan,  
  • role: Corresponding author通信作者
  • Affiliation:

    Institute of Biomedical Precision Testing and Instrumentation,College of Artificial Intelligence,Taiyuan University of Technology,Jinzhong 030600,China

  • Email:mengxuejuan@tyut.edu.cn
  • Introduction:孟雪娟,博士,副教授,研究方向:智能装备制造与生物医学应用,E-mail:mengxuejuan@tyut.edu.cn
MENG Xue-juan*,  
  • Affiliation:

    Institute of Biomedical Precision Testing and Instrumentation,College of Artificial Intelligence,Taiyuan University of Technology,Jinzhong 030600,China

LI Xiao-chun

Resumo

β2-microglobulina é um marcador importante que reflete os primeiros danos na função renal na nefropatia diabética. A detecção rápida e precisa é fundamental para o diagnóstico precoce e monitoramento da doença. Este estudo desenvolveu um sistema de reagente imuno-turbidimétrico reforçado com látex para a detecção quantitativa de β2-microglobulina. O imunolátex foi preparado conjugando anticorpos anti-β2-microglobulina na superfície de microesferas de látex de poliestireno carboxilado. Na presença do antígeno, formam-se complexos imunológicos que causam mudança na turbidez da solução, permitindo a detecção quantitativa de β2-microglobulina. Além disso, o sistema foi integrado a uma plataforma de detecção imuno-turbidimétrica baseada em smartphone, realizando a coleta portátil e análise dos sinais por meio do sensor de luz ambiente embutido no telefone. O sistema apresentou boa resposta linear na faixa de 0~60 mg/L, com limite de detecção de 0,85 mg/L. A taxa de recuperação adicionada variou de 93,5% a 106%, e o coeficiente de variação entre lotes foi de 5,7% a 9,9%, com bom desempenho em precisão, repetibilidade e especificidade. Os resultados dos reagentes artesanais foram consistentes com os dos reagentes comerciais (r²=0,9884), e os resultados da plataforma imuno-turbidimétrica por smartphone mostraram alta correlação com os do analisador enzimático (r²=0,9935). Este sistema de reagentes, combinado com a plataforma de detecção por smartphone, apresenta vantagens como operação simples, detecção rápida, baixo custo e alta portabilidade, fornecendo uma solução técnica viável para a detecção imediata de biomarcadores da nefropatia diabética e sua aplicação na atenção básica.

Palavras-chave

nefropatia diabética;β2-microglobulina;imuno-turbidimetria reforçada com látex;smartphone;detecção imediata

References

  1. 1.
    Thomas B. Curr. Diabetes Rep.,2019,19(4):18.
  2. 2.
    International Diabetes Federation. Diabetes Atlas. [2026-01-16]. .
  3. 3.
    Zhao H S,Sun D,Wang S,Liu Y,Zhao X J,Tian W Q,Dou X H,Liu J L,Xu J Y,Peng L,Sun S R,Xia Y L,Xu X M,Wang C,Wang D,Zhao G H,Wang X,Weng H Z,Ding F Y,Xing P P,Zhang F Y,Liu S Y,Yan W J,Tao L. Nat. Commun.,2025,16(1):7846.
  4. 4.
    De Vries J K,Levin A,Loud F,Adler A,Mayer G,Pena M J. Diabetes Obes. Metab.,2018,20 (S3):24-29.
  5. 5.
    Ay E,Marakoğlu K,Kizmaz M,Ünlü A. J. Clin. Lab. Anal.,2016,30(6):972-977.
  6. 6.
    Liu H,Feng J G,Tang L L. Front. Physiol.,2022,13:1020443.
  7. 7.
    Winchester J F,Salsberg J A,Levin N W. Adv. Ren. Replace. Ther.,2003,10(4):279-309.
  8. 8.
    Tramonti G,Cipollini I,Annichiarico C,Lorusso P,Panicucci E,Mariani G,Barsotti G. J. Nephrol.,2012,25(6):976-982.
  9. 9.
    Herrero-Morín J D,Málaga S,Fernández N,Rey C,Diéguez M A,Solís G,Concha A,Medina A. Crit. Care,2007,11(3):R59.
  10. 10.
    Floege J,Bartsch A,Schulze M,Shaldon S,Koch K M,Smeby L C. J. Lab. Clin. Med.,1991,118(2):153-165.
  11. 11.
    Argyropoulos C P,Chen S S,Ng Y H,Roumelioti M E,Shaffi K,Singh P P,Tzamaloukas A H. Front. Med.,2017,4:73.
  12. 12.
    Inker L A,Tighiouart H,Coresh J,Foster M C,Anderson A H,Beck G J,Contreras G,Greene T,Karger A B,Kusek J W,Lash J,Lewis J,Schelling J R,Navaneethan S D,Sondheimer J,Shafi T,Levey A S. Am. J. Kidney Dis.,2016,67(1):40-48.
  13. 13.
    Shafi T,Michels W M,Levey A S,Inker L A,Dekker F W,Krediet R T,Hoekstra T,Schwartz G J,Eckfeldt J H,Coresh J. Kidney Int.,2016,89(5):1099-1110.
  14. 14.
    Le T N,Chen H Y,Lam X M,Wang C C,Chang H C. Anal. Chem.,2023,95(32):12080-12088.
  15. 15.
    Tugirimana P L,De Clercq D,Holderbeke A L,Kint J A,De Cooman L,Deprez P,Delanghe J R. J. Vet. Diagn. Invest.,2011,23(2):308-311.
  16. 16.
    Conde-Sánchez M,Roldán-Fontana E,Chueca-Porcuna N,Pardo S,Porras-Gracia J. Clin. Biochem.,2010,43(10/11):921-925.
  17. 17.
    Seegmiller J C,Sviridov D,Larson T S,Borland T M,Hortin G L,Lieske J C. Clin. Chem.,2009,55(11):1991-1994.
  18. 18.
    Tugirimana P L,Holderbeke A L,Kint J A,Delanghe J R. Clin. Chem. Lab. Med.,2009,47(11):1417-1422.
  19. 19.
    Yamashita K,Takebayashi S,Murata W,Hirai N,Ito Y,Mitsui M,Saito M,Sato K,Terada M,Niizeki N,Suzuki A,Ogitani K,Fujikawa T,Komori M,Inoue N,Arai N,Maekawa M. Diagnostics,2023,13(18):2935.
  20. 20.
    Jindakaew J,Kaewsaneha C,Ratanatawanate C,Lebaz N,Suwannin P,Zine N,Opaprakasit P,Elaissari A. Colloids Surf. A,2024,685:133108.
  21. 21.
    Bargnoux A S,Barrot A,Fesler P,Kuster N,Badiou S,Dupuy A M,Ribstein J,Cristol J P. Clin. Biochem.,2014,47(16/17):250-253.
  22. 22.
    Makris K,Stefani D,Makri E,Panagou I,Lagiou M,Sarli A,Lelekis M,Kroupis C. Clin. Biochem.,2015,48(18):1291-1297.
  23. 23.
    Yang X,Shu W X,Wang Y Q,Gong Y,Gong C Y,Chen Q S,Tan X T,Peng G D,Fan X D,Rao Y J. Biosens. Bioelectron.,2019,131:60-66.
  24. 24.
    Taron W,Phooplub K,Sanchimplee S,Piyanamvanich K,Jamnongkan W,Techasen A,Phetcharaburanin J,Klanrit P,Namwat N,Khuntikeo N,Boonmars T,Sithithaworn P,Ouiganon S,Kanatharana P,Thavarungkul P,Buranachai C,Loilome W,Ngeontae W. Sens. Actuators B,2021,348:130705.
  25. 25.
    Liang M Q,Wang Z H,Liu Y,Dong C,Gong X J. J. Instrum. Anal.(梁美琪,王子涵,刘洋,董川,弓晓娟. 分析测试学报),2024,43(1):182-190.
  26. 26.
    Mesas Gómez M,Julián E,Armengou L,Pividori M I. Talanta,2024,275:126106.
  27. 27.
    Liu M Y,Li S P,Zhao J. J. Instrum. Anal.(刘美廷,李绍平,赵静. 分析测试学报),2021,40(5):777-784.
  28. 28.
    Lee K C,Lee K,Jung J,Lee S H,Kim D,Lee S A. ACS Photonics,2021,8(5):1307-1315.
  29. 29.
    Tamiya E,Osaki S,Nagai H. Biosens. Bioelectron.,2024,252:116083.
  30. 30.
    Dutta S. TrAC Trends Anal. Chem.,2019,110:393-400.
  31. 31.
    Wang T T,Guo K,Hu X M,Liang J,Li X D,Zhang Z F,Xie J. Chemosensors,2020,8(1):10.
  32. 32.
    Zhao L,Dong B Y,Li W,Zhang H F,Zheng Y S,Tang C,Hu B,Yuan S F. IEEE Sens. J.,2021,21(4):4451-4461.
  33. 33.
    Zhou P. Rapid Detection Technology for Acute Myocardial Infarction Markers Based on Smartphone Immunoturbidimetry. Shanxi:Taiyuan University of Technology (周鹏. 基于智能手机免疫比浊法的急性心肌梗死标志物快速检测技术. 山西:太原理工大学),2022.

Leia o texto completo