Determinação de 9 tipos de bifenilos policlorados em águas subterrâneas por extração micro-sólida assistida por vácuo no espaço de cabeça / cromatografia gasosa-espectrometria de massa

  • role: First author第一作者
  • Affiliation:

    Zhenjiang Environmental Monitoring Center of Jiangsu Province,Zhenjiang 212000,China

ZHOU Xu-ping,  
  • Affiliation:

    Zhenjiang Environmental Monitoring Center of Jiangsu Province,Zhenjiang 212000,China

HE Yuan-yuan,  
  • Affiliation:

    Zhenjiang Environmental Monitoring Center of Jiangsu Province,Zhenjiang 212000,China

LIU Jun,  
  • role: Corresponding author通信作者
  • Affiliation:

    Zhenjiang Environmental Monitoring Center of Jiangsu Province,Zhenjiang 212000,China

  • Email:360300440@qq.com
  • Introduction:殷伟庆,硕士,正高级工程师,研究方向:环境监测,E-mail:360300440@qq.com
YIN Wei-qing*

Resumo

Para enfrentar a falta de alguns compostos policlorados bifenilos (PCBs) no monitoramento da qualidade da água, foi empregada a extração micro-sólida assistida por vácuo no espaço de cabeça (Vac-HS-SPME) para concentração, seguida de detecção por cromatografia gasosa-espectrometria de massa (GC-MS), estabelecendo um novo método ambiental, eficiente e sensível para nove tipos de PCBs em águas subterrâneas. Otimizando as fibras de extração, temperatura, tempo e velocidade de agitação, foram determinadas as melhores condições de extração: definição da fibra PDMS/DVB de 65 μm, extração a 70 ℃ com agitação a 500 rpm por 40 minutos. Na faixa de concentração de massa de 0,02 a 2,0 μg/L, os nove PCBs apresentaram boa linearidade, com coeficiente de correlação linear (r) de 0,9981 a 0,9994, e limite de detecção do método entre 0,002 e 0,016 μg/L. A recuperação da adição dos nove PCBs foi de 78,9% a 115%, com desvio padrão relativo (n=6) de 2,8% a 12%. Comparado à extração micro-sólida convencional em espaço de cabeça (HS-SPME), Vac-HS-SPME apresentou maior sensibilidade e eficiência de extração. O método é simples, ambientalmente amigável e sensível, e foi aplicado com sucesso em amostras reais de águas subterrâneas, proporcionando uma nova ferramenta técnica para análise qualitativa e quantitativa de PCBs em amostras de água ambiental.

Palavras-chave

Extração micro-sólida assistida por vácuo no espaço de cabeça; cromatografia gasosa-espectrometria de massa; águas subterrâneas; bifenilos policlorados

References

  1. 1.
    Helou K,Harmouche-Karaki M,Karake S,Narbonne J. Chemosphere,2019,231:357-368.
  2. 2.
    Da Silva M R A,Rodrigues E D O,Espanhol-Soares M,Silva F,Kondo M,Gimenes R. Environ. Technol.,2019,40(10):1298-1305.
  3. 3.
    Ganneru S,Seetha B S,Mudiam M K R. J. Chromatogr. A,2023,1708:464338.
  4. 4.
    Chen G,Cao L,Sun Y H,Jiang J,Xian Q M. China Meas. Test(陈刚,曹鎏,孙艳华,蒋娟,鲜啟鸣. 中国测试),2022,48(10):8-15.
  5. 5.
    GB/T 14848-2017. Standard for Groundwater Quality. National Standards of the People's Republic of China(地下水质量标准. 中华人民共和国国家标准).
  6. 6.
    HJ 715-2014. Water Quality Determination of Polychlorinated Biphenyls(PCBs) Gas Chromatography Mass Spectrometry. National Ecological and Environmental Standards of the People's Republic of China(水质多氯联苯的测定 气相色谱-质谱法. 中华人民共和国国家生态环境标准).
  7. 7.
    Kamp J,Dierkes G,Schweyen P N,Wick A,Ternes T A. Environ. Sci. Technol.,2023,57(12):4806-4812.
  8. 8.
    Ediagbonya T F,Ediagbonya O R,Bagbe A S,Ajibare O A,Akinola T M,Obebe F C. Toxicol. Environ. Health Sci.,2024,16(4):503-513.
  9. 9.
    Santini S,Baini M,Martellini T,Bissoli M,Galli M,Concato M,Fossi M C,Cincinelli A. Food Chem.,2024,443:138582.
  10. 10.
    Šimić I,Mendaš G,Pehnec G. J. Chromatogr. A,2020,1633:461599.
  11. 11.
    Wiltschka K,Wolkersdorfer C,Düring R A,Böhm L. ACS ES&T Water,2023,3(11):3474-3484.
  12. 12.
    Li B Y,Wang Z,Chen J,Qiu H D. J. Instrum. Anal.(李丙阳,王钊,陈佳,邱洪灯. 分析测试学报),2025,44(1):172-179.
  13. 13.
    Hou X R,Tong K X,Chang Q Y,Zhang H Y,Chen H,Li X Y,Zhang J L,Li L. J. Instrum. Anal.(侯新茹,仝凯旋,常巧英,张虹艳,陈辉,李相阳,张佳琳,李玲. 分析测试学报),2025,44(2):275-284.
  14. 14.
    Syrgabek Y,Alimzhanova M,Yegemova S,Batyrbekova S. Adv. Sample Prep.,2024,11:100123.
  15. 15.
    Pateraki A,Psillakis E. J. Chromatogr. A,2025,1740:465556.
  16. 16.
    HJ 168-2020. Technical Guideline for the Development of Environmental Monitoring Analytical Method Standards. National Ecological and Environmental Standards of the People's Republic of China(环境监测分析方法标准制订技术导则. 中华人民共和国国家生态环境标准).
  17. 17.
    GB/T 27417-2017. Comformity Assessment-Guidance on Validation and Verification of Chemical Analytical Methods. National Standards of the People's Republic of China(合格评定化学分析方法确认和验证指南. 中华人民共和国国家标准)
  18. 18.
    Felli N,Migneco L M,Francolini I,Gentili A,Hernández-Borges J. Talanta,2025,290:127773.
  19. 19.
    Manousi N,Efstratiadis G,Kabir A,Rosenberg E,Zachariadis G,Kalogiouri N P. Microchem. J.,2024,206:111673.
  20. 20.
    Jiang J,Liu L,Shen L,Li J,Xu Q,Li Z,Qiu H. J. Chromatogr. A,2025,1740:465583.
  21. 21.
    Zhang L,Li L,Zhang D Y,Zhang S G,Chen Z D. Chin. J. Anal. Lab.(张利,李莉,张登耀,张盛贵,陈自弟. 分析试验室),2024,43(3):409-414.
  22. 22.
    Chen Y J,Pan H H,Sun Y,Liang Y. Phys. Test. Chem. Anal.:Chem. Anal.(陈漪洁,潘慧慧,孙扬,梁玉. 理化检验-化学分册),2022,58(11):1315-1320.

Leia o texto completo

The above content is generated by Large Model Translation. The translated content is for reference only. We do not assume any commercial or legal responsibilty for any consequences arising from the use of our website